Manual for automatic external defibrillator (AED)

The article was written by MSc Pham Duc Luong - Emergency Doctor - Emergency Department - Vinmec Times City International General Hospital
In many countries around the world, automatic external defibrillators (AEDs) are available in many public places, including shopping malls, schools, apartment buildings, train stations, and airports. The machine will analyze the victim's heart rate and display or notify the user of the action to take at each stage.

1. Circulatory arrest


When the heart stops beating, circulatory arrest occurs. The danger is that circulatory arrest can happen to the average person, with no medical history, at any time and in any place. The most common cause is abnormal heart rhythm disturbances, especially ventricular fibrillation. This irregular rhythm can occur when the heart muscle is damaged by a heart attack or when not enough oxygen reaches the heart.
A machine called an automated external defibrillator (AED) is used to correct the heart's rhythm by delivering an electric shock. This device is designed to be extremely compact, allowing even people with no experience or medical knowledge to use it to increase the survival of cardiac arrest victims in the hospital as well as in the area. outside the hospital.
In most cases, rescuers need to begin CPR while waiting for the AED to arrive. Once brought in, continue CPR while preparing to start the machine and attach the electrodes to the victim's chest.
Hô hấp nhân tạo
Cần tiến hành ấn ngực và hô hấp nhân tạo cho bệnh nhân trong khi đợi máy AED

2. Steps to use the AED


Turn on the AED and remove the electrode pads from the sealed package. Take off or cut through clothing and wipe sweat off the victim's chest. Tear off the electrode sheath, take and stick the pads to the victim's chest at the indicated locations. Place the first electrode pad on the upper right side just below the victim's collarbone.
Sử dụng máy AED
Lấy và dán các miếng đệm điện cực vào các vị trí trên ngực nạn nhân
3. Place the second pad on the left side, just below the victim's armpit (above). Make sure the mattress has a long axis along the head-to-toe axis of the victim's body.
4. The AED will start analyzing the heart rate. Make sure that no one touches the victim. Follow the visual and/or verbal instructions given by the machine.

3. Attention when using


Make sure that no one touches the victim while the rhythm analyzer and shock button is pressed as this will affect the analysis results of the AED and pose a risk of electric shock.
Do not turn off the AED or disassemble the electrode plate of the AED, even if the victim appears to have recovered because cardiac arrest may recur and may require repeated shocks.
The use of AEDs is sometimes complicated by underlying medical conditions, external factors, clothing, or causes of cardiac arrest. The safety of all people involved should always be the first consideration of the first responder.
Clothing : Clothing or any jewelry that interferes with electrode placement should be removed or removed. The amount of normal breast hair should not be an issue, but if it prevents good contact between the skin and the electrode pad, it should be shaved off. Ensure that any metal is removed from the area where the electrode pad will be attached. Take off clothing that contains metal, such as underwire bras.
Hồi sức cấp cứu
Nên cởi bỏ đồ và cạo bớt lông ngực để tăng hiệu quả tiếp xúc giữa da và miếng điện cực

External factors : Excessive water or sweat on the chest can reduce the effectiveness of the electric shock, so the chest must be dry. If victim is rescued from water, dry chest before applying AED patches. If the victim is unconscious after being electrocuted, begin performing basic CPR as soon as the power is removed. Medical conditions: Some heart disease victims receive pacemakers or implantable defibrillators. This will not prevent you from using the AED. However, if you see or feel a device under the skin of your chest, do not place the electrode pad directly on it. If the victim has a patch such as a nitroglycerin patch on the chest, remove it before applying the AED electrode. Pregnant victim: There are no contraindications to the use of AEDs in pregnant women. However, increased breast size can cause problems with electrode placement. Therefore, to place the AED pad correctly, it is necessary to gently push one or both breasts to the right and stick the electrode pad in the lateral position of the left breast, not on the fetal breast. extra. Vinmec International General Hospital has applied electrocardiographic shock technique in the treatment of arrhythmias. Electrocardiography at Vinmec is performed methodically and according to standard procedures by a team of highly qualified medical professionals, modern machinery system, thus giving positive treatment results, bringing the possibility of treatment. quick recovery.

Để đặt lịch khám tại viện, Quý khách vui lòng bấm số HOTLINE hoặc đặt lịch trực tiếp TẠI ĐÂY. Tải và đặt lịch khám tự động trên ứng dụng MyVinmec để quản lý, theo dõi lịch và đặt hẹn mọi lúc mọi nơi ngay trên ứng dụng.

Bài viết này được viết cho người đọc tại Sài Gòn, Hà Nội, Hồ Chí Minh, Phú Quốc, Nha Trang, Hạ Long, Hải Phòng, Đà Nẵng.

65 lượt đọc

Dịch vụ từ Vinmec

Bài viết liên quan